mgr inż. Patryk Sokołowski | Gdańsk University of Technology

Page content

mgr inż. Patryk Sokołowski

Contact:

email:
patsokol@pg.edu.pl
website:
https://mostwiedzy.pl/patryk-sokolowski,1082173-1

Positions:

Engineering and Technical Specialist

mgr inż. Patryk Sokołowski

Publications:

  1. Fiber optic sensors have gained popularity over the last few decades. This is due to their numerous advantages, such as good metrological parameters, biocompatibility and resistance to magnetic and electric fields and environmental pollution. However, those built from glass fiber have one main disadvantage—they are fragile, meaning they can be easily damaged, even by the presence of vibration. Due to the great progress made by...

    Full text to download in external service

  2. Publication

    - Scientific Reports - Year 2024

    The rapid and sensitive indicator of inflammation in the human body is C-Reactive Protein (CRP). Determination of CRP level is important in medical diagnostics because, depending on that factor, it may indicate, e.g., the occurrence of inflammation of various origins, oncological, cardiovascular, bacterial or viral events. In this study, we describe an interferometric sensor able to detect the CRP level for distinguishing between...

    Full text to download in external service

  3. In this article we present the novel spectroscopy method supported with machine learning for real-time detection of infectious agents in wastewater. In the case of infectious diseases, wastewater monitoring can be used to detect the presence of inflammation biomarkers, such as the proposed C-reactive protein, for monitoring inflammatory conditions and mass screening during epidemics for early detection in communities of concern,...

    Full text available to download

  4. The study presents an optical method supported by machine learning for discriminating urinary tract infections from an infection capable of causing urosepsis. The method comprises spectra of spectroscopy measurement of artificial urine samples with bacteria from solid cultures of clinical E. coli strains. To provide a reliable classification of results assistance of 27 algorithms was tested. We proved that is possible to obtain...

    Full text available to download

  5. Publication

    In this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...

    Full text available to download

data from Bridge of Knowledge open in new tab Bridge of Knowledge

Projects: