dr inż. Krzysztof Dobrzyński | Politechnika Gdańska

Treść strony

dr inż. Krzysztof Dobrzyński

Kontakt:

email:
krzysztof.dobrzynski@pg.edu.pl
strona:
https://mostwiedzy.pl/krzysztof-dobrzynski,14935-1

Zajmowane stanowiska:

Adiunkt

miejsce pracy:
Katedra Elektroenergetyki
Budynek Wydziału Elektrotechniki i Automatyki, 314
telefon:
(58) 347 17 98
dr inż. Krzysztof Dobrzyński

Publikacje:

  1. Publikacja

    The current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...

    Pełny tekst do pobrania w portalu

  2. The author present a method for the estimation of selected synchronous generator model and AVR parameters using a gradient and a genetic algorithm. The paper shows an example of model parameter estimation for a turbogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test

    Pełny tekst do pobrania w portalu

  3. Publikacja

    - Automatyka Elektryka Zakłócenia - Rok 2023

    The paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.

    Pełny tekst do pobrania w serwisie zewnętrznym

  4. Publikacja

    - ENERGIES - Rok 2020

    Cable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...

    Pełny tekst do pobrania w portalu

  5. Load currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...

    Pełny tekst do pobrania w portalu

dane pochodzą z portalu MOST Wiedzy otwiera się w nowej karcie MOST Wiedzy