  1. The article deals with the issue of the numerical analysis of the magnetic field occurring around the transformer after it has been powered down. The main goal of this analysis was to examine if it is possible to identify the residual fluxes in the transformer legs based on this fields’ measurements. It was also intended to determine the type and the location of magnetic sensors. Numerical analysis of the magnetic field was performed....

    Pełny tekst do pobrania w serwisie zewnętrznym

  2. Publikacja

    - Rok 2017

    The article presents the numerical analysis of the magnetic field that occurs around the transformer after it has been switched off. The purpose of this analysis was to determine if it is possible to define the residual fluxes in the legs of transformer based on the measurements of this field. These studies have allowed us to determine the quantity and location of the sensors. The influence of the Earth's magnetic field has also...

    Pełny tekst do pobrania w serwisie zewnętrznym

  3. Publikacja

    - Rok 2017

    The article presents the method of calculating the residual induction in transformer columns. The method is based on measurement of the magnetic induction in selected points around the transformer core. The values of residual induction are calculated as linear combination of the results of measurement.

    Pełny tekst do pobrania w serwisie zewnętrznym

  4. Publikacja

    - Rok 2017

    Power electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....

    Pełny tekst do pobrania w serwisie zewnętrznym

  5. Publikacja

    - Rok 2016

    Monografia obejmuje swoim zakresem szereg zagadnień dotyczących prądów załączeniowych transformatora w stanie jałowym. Zawiera szczegółową analizę czynników, które mają wpływ na przebiegi tych prądów, a zwłaszcza na ich wartości szczytowe. Wnikliwej analizie poddano jeden z głównych czynników kształtujących prąd załączeniowy transformatora, którym jest magnetyzm szczątkowy rdzenia. Przeanalizowano, jaki wpływ na stan namagnesowania...